Encuentre similares con IA
Perfil de impresión(0)
Archivo de modelo(0)
Publicado:2026-01-25 06:28:41
0
0
Nozzle-to-Probe offsets { X, Y, Z }
NOZZLE_TO_PROBE_OFFSET { 0, -37, -0.45 } //example
// the last value " -0.45" will depend on how low or high you will adjust the adapter with the screws
But all the values can be found very easily. Make sure that you have the expanded probe, lower than your nozzle, do a homing, take a sticker, put it under the nozzle, make a mark right under the nozzle on the sticker, use micro-steps, and position the probe above the mark. You will see the values of X and Y on the screen or you can count your micro-steps. Then use the same sticker to adjust Z by lowering your hothead until you feel a little friction when you move the sticker. The same you will see the value of Z on the screen